Allow to configure Trigger Window in seconds, not by counting samples
This would allow to have triggered mode as well for the power-supply class - mode: "DISJUNCT_SINGLE_SAMPLE" Currently, `CircularBufferManagerBase::pre_trigger_samples_` and `CircularBufferManagerBase::post_trigger_samples_` are used in `updateTriggerWindowIter` in order to update the Trigger Window. The current concept only works for signal-sources which already provide data in a triggered way (Data-Packages of size 'pre+post samples'). The idea is, to as well provide 'triggered' data-Windows for the streaming data (`CircularBufferManagerBase` with ClientNotificationType::TRIGGERED). Since the samples of streaming data are not necessarily equidistant (modes `DISJUNCT_SINGLE_SAMPLES` and `DISJUNCT_MULTI_SAMPLES`), the Trigger-Window would need to be calculated in seconds (instead of n_samples). Required changes: - `CircularBufferManagerBase::pre_trigger_samples_` --> `CircularBufferManagerBase::pre_trigger_time_` - `CircularBufferManagerBase::post_trigger_samples_` --> `CircularBufferManagerBase::post_trigger_time_` - `CircularBufferManagerBase::setTriggerSamples` needs to calculate *_time_ for continuous modes and throw an error for disjunct modes. - New method `CircularBufferManagerBase::setTriggerTime` to set the time. - Modification of the method `updateTriggerWindowIter` to work time-based - Make sure that Trigger Windows are generated for Streaming channels (Possibly changes in `pushBackDataFinished` are required … to be checked where else) - Unit-Tests for triggered + disjunct in `CircularBufferManagerBaseTest`