Updates in Streaming mode are not continous - gaps between updates whenever there is a new ref trigger
Whenever there is a new ref-trigger, the related client updates will have a time-gap. Usually the gap will be 30µs, though seldom gaps up to 5000µs were observed)
Setup:
- "digitizertestclient", Testcase "2"
- dal004, ps4000Stream_and_ps4000Trig.grc, 10MS or 20MS, downsampling: 1000, only command events (one per second, not simulated ... when using simulated events, the gap is still there, but very unsteady ... possibly related to 1.2sec. sim. intervals)
- Number of sinks, or samp_rate of the sink seems not to matter (same for 10kS and 1kS)
- same for update frequency 25Hz and 1Hz
- directly putting TimeSink after the Digitizer block does not help
- Can be observed with/without downsampling. (Best test this without downsampling to prevent other side-effects)
- Modification of other Digitizer-Block parameters does not help.
Probably caused by https://gitlab.com/al.schwinn/gr-digitizers/-/issues/28 ... to be checked